Tutorial centre fire inspection
In Hong Kong, many tutorial centres occupy shop units, commercial floors or mall premises. After-school sessions can be crowded, and desks, teaching materials or storage often encroach on escape routes. Whatever the size of the premises, clear exits and fire service installations and equipment (FSI) that work are essential to protect students, tutors and visitors.
路佳安全 (STMHK) is Shinning Trading & Manufacturing Co.Ltd., a Registered Fire Service Installation Contractor (RC3/861). Established in 1982, we have more than 40 years’ experience in Hong Kong. We can help tutorial centres with a site assessment, supply and installation of approved fire equipment, annual inspection and issue of the Certificate of Fire Service Installation and Equipment (FS251), and briefing for the person in charge. Where Education Bureau registration or a Fire Services Certificate is involved, we can also support the related technical documents.
Under sections 3(1) and 10 of the Education Ordinance (Cap. 279), an institution that provides education for 20 or more persons during any one day, or for 8 or more persons at any one time, generally has to be registered or provisionally registered with the Education Bureau. The Bureau classifies private schools offering tutorial, commercial, language, computer and similar courses as “private schools offering non-formal curriculum”. Even where the Education (Exemption) (Private Schools Offering Non-formal Curriculum) Order (Cap. 279F) exempts certain provisions on fees, teachers, the principal and holidays, the duty to register is not waived. If registration is required and the premises were not originally designed as a school, a Fire Services Certificate issued by the Fire Services Department (FSD) is a prerequisite. Separately, any FSI installed in the premises must be kept in efficient working order and inspected at least once every 12 months by a registered FSI contractor under regulation 8 of the Fire Service (Installations and Equipment) Regulations (Cap. 95B), with an FS251 issued. Education Bureau Circular No. 12/2026 also reminds aided, DSS, caput and private schools to keep FSI in good condition. Operators should follow the latest official requirements for their premises. See also School fire safety and Fire Solutions.
Do you know your fire service installations are kept in working order?
Click the equipment marked 1 to 4 on the diagram for daily care and annual inspection points. Drag the slider below from the normal state into a fire scene: general lighting goes out, the rooms go dark, the emergency lights and EXIT sign stay visible, and cartoon fire and smoke appear. You may also press “Fire response (when equipment works)” to watch evacuation along the planned route. This demonstration assumes the required inspections have already been carried out and is not a real fire drill.
This material is general information and is not legal advice. The fire-response demonstration assumes the equipment is in working order and is not a real fire drill. Actual evacuation must follow the premises fire escape plan and instructions from those in charge. 路佳安全|stmhk.com
What we cover
• Fire safety advice and assessment: a site visit to review layout, escape routes and existing installations, identify risks, and provide practical recommendations
• Installation of approved equipment: supply and install portable extinguishers approved by the Director of Fire Services, and related fire equipment, as required for the premises
• Annual inspection and maintenance: inspection at least once every 12 months under Cap. 95B regulation 8, with an FS251 issued
• Staff briefing: basic fire-safety knowledge, escape points and the correct use of extinguishers for tutors or the person in charge
• Technical support for registration or licensing documents: help with FS251 and related technical papers where EDB registration or an FSD Fire Services Certificate is required
Contact us
You are welcome to WhatsApp 9122 1697 or email sales@stmhk.com. Tel: 2474 2996. Business hours: Monday to Friday 10:00–18:00; closed on Saturday and Sunday.
Contact 路佳安全
You can also contact us on WhatsApp so we can better understand your needs.
STMHK selected fire equipment for tutorial centres

Approved portable equipment and annual inspection for classrooms and shop units.
Learn more →
Fire separation along escape routes in commercial or shop premises.
Learn more →
Evacuation support when after-school sessions are crowded.
Learn more →
Fire protection advice for tablets, phones and charging areas.
Learn more →Fire safety tips
Keep the annual inspection on schedule
FSI in the premises must be kept in efficient working order and inspected at least once every 12 months by a registered contractor, with an FS251 issued.
Do not let desks block the exits
Desks, storage and teaching materials commonly encroach on escape routes in tutorial centres. Keep exits, corridors and the approaches to FSI clear.
Watch charging and electrical loads
Tablets, phones and extension leads are common in classrooms. Keep charging areas ventilated and away from escape routes. Larger charging facilities should follow the latest FSD circulars.
The person in charge must know the way out
After-school sessions can be crowded. Tutors and the person in charge should know the alarm, escape routes and assembly point, and regularly check that routes are not obstructed.
Register once the numbers are reached
If a centre provides education for 20 or more persons during any one day, or for 8 or more at any one time, it generally has to be registered or provisionally registered with the Education Bureau. The Cap. 279F exemption order does not waive registration. Where registration is required and the premises are not purpose-built as a school, a Fire Services Certificate is a prerequisite.
Related official resources
Education Ordinance (Cap. 279)
Official source · Opens in a new window
Open →Education Regulations (Cap. 279, sub. leg. A)
Official source · Opens in a new window
Open →Education (Exemption) (Private Schools Offering Non-formal Curriculum) Order (Cap. 279F)
Official source · Opens in a new window
Open →Education Bureau: Private Schools Offering Non-formal Curriculum
Official source · Opens in a new window
Open →Education Bureau: Information on application for school registration
Official source · Opens in a new window
Open →EDB registration guide, Appendix 3: Fire Services Department fire safety requirements
Official source · Opens in a new window
Open →EDB registration guide, Appendix 8: Procedures for safety certificates — kindergartens and tutorial schools
Official source · Opens in a new window
Open →Education Bureau: Points to note when choosing a private school offering non-formal curriculum
Official source · Opens in a new window
Open →FSD: The Role of Fire Services Department in the Registration of Non-designed Schools
Official source · Opens in a new window
Open →FSD: Fire safety requirements for licensed / registered premises — Schools
Official source · Opens in a new window
Open →Fire Service (Installations and Equipment) Regulations (Cap. 95B)
Official source · Opens in a new window
Open →Education Bureau Circular No. 12/2026: Fire Service Installation or Equipment of School Premises
Official source · Opens in a new window
Open →Fire Protection Notice No. 11: Proper use and maintenance of various types of fire extinguishers
Official source · Opens in a new window
Open →FSD: Portable equipment, fire service installations and fire safety products requiring acceptance
Official source · Opens in a new window
Open →FSD Circular No. 3/2025: Fire safety requirements for battery rooms and charging facilities (where applicable)
Official source · Opens in a new window
Open →Frequently asked questions
If you cannot find an answer, please contact us: sales@stmhk.com · WhatsApp: 9122 1697
Does every tutorial centre have to be registered with the Education Bureau?
Not necessarily. Under sections 3(1) and 10 of the Education Ordinance, an institution that provides education for 20 or more persons during any one day, or for 8 or more persons at any one time, generally has to be registered or provisionally registered with the Education Bureau. The Bureau classifies private schools offering tutorial, commercial, language, computer and similar courses as “private schools offering non-formal curriculum”. A classroom below those numbers may not be a “school” under the Ordinance; the Bureau’s current interpretation should be followed. Even where such a private school is exempted by the Education (Exemption) (Private Schools Offering Non-formal Curriculum) Order (Cap. 279F) from certain provisions on fees, teachers, the principal and holidays, it must still be registered — the Order does not waive registration. If registration is required and the premises were not originally designed as a school, an FSD Fire Services Certificate is a prerequisite. We can help with annual inspection and technical documents; eligibility for registration should be confirmed with the Education Bureau.
How often must the fire service installations be inspected?
Under regulation 8 of the Fire Service (Installations and Equipment) Regulations (Cap. 95B), FSI installed in the premises must be kept in efficient working order and inspected at least once every 12 months by a registered FSI contractor, who issues an FS251. STMHK is a registered contractor (RC3/861) and can carry out the inspection and certificate. This annual duty is separate from whether the centre is currently applying for school registration.
If the premises were not originally designed as a school, is a Fire Services Certificate required before registration?
Yes. FSD states that, for schools in premises not originally designed for school use, the Fire Services Certificate is evidence that the fire safety requirements have been met, and is a prerequisite for registration. Applicants usually need certificates issued by a registered contractor (for example the FSI/314 series and/or a valid FS251) and an inspection by the FSD Licensing Office. Please refer to the official FSD materials.
Should the FS251 be displayed after the annual inspection?
After the inspection, the contractor issues an FS251. Education Bureau Circular No. 12/2026 reminds aided schools to display the endorsed FS251 at a conspicuous location in the premises for inspection by FSD; the circular also applies to DSS, caput and private schools in respect of keeping FSI in good condition and the annual inspection. If a tutorial centre is a private school required to be registered, it should follow the latest EDB and FSD requirements on keeping and displaying the certificate. Even where the circular does not specifically address an unregistered classroom, displaying the certificate in a conspicuous place is common practice.